| PRIMARY FAULT | SECONDARY FAULT | CAUSE | ACTION |
|---|---|---|---|
| Not Flushing | Pump Not Running | Fuse Blown | Remove/Check/Replace |
| No 12V | Check Main Fuse in Control Panel | ||
| Check Wiring/Connections | |||
| Microswitch Ass. Fault | Remove/Check/Replace | ||
| Faulty Pump | Remove/Check/Replace | ||
| Pump Running | Flush Tube Disconnected | Reattach | |
| Air Lock in Pump | Unlatch Pump and Shake |
| PRIMARY FAULT | SECONDARY FAULT | CAUSE | ACTION |
|---|---|---|---|
| Level Indicator Fault | Stuck in Half Way Position | Float in Cassette Detached/Leaking | Replace Float |
| Magnet Detached | Reattach |
| PRIMARY FAULT | SECONDARY FAULT | CAUSE | ACTION |
|---|---|---|---|
| Waste Water in Cassette Compartment | None | Lip Seal Degraded | Replace Lip seal |
| Clean Water in Cassette Compartment | None | Drain Tube Perished/Split | Replace With Modification Kit |
| Waste Water Leak When Tipping | None | Worn Vent Seal | Replace |